{"product_id":"generac-10kw-air-cooled-home-standby-with-16-circuit-100-amp-transfer-switch-7172","title":"Generac 10kW Air-Cooled Home Standby with 16-Circuit, 100 Amp Transfer Switch - 7172","description":"Generac 10kW Air-Cooled Home Standby with 16-Circuit, 100 Amp Transfer Switch - 7172  \u003cbr\u003e\u003cbr\u003e  Model Number: 7172  \u003cbr\u003e  \u003cp\u003eThe Generac 10kW Air-Cooled Home Standby with 16-Circuit, 100 Amp Transfer Switch safeguards your household's essential electrical circuits, ensuring they remain operational during power outages. It is a cost-effective automatic standby generator, providing crucial protection at approximately half the price of installing central air conditioning.    \u003c\/p\u003e\u003cp\u003eMobile Link™ Remote Monitoring, included with every Guardian Series Home standby generator, enables you to check your generator's status from anywhere worldwide using a smartphone, tablet, or PC. This feature allows easy access to the current operational status and maintenance notifications.  \u003c\/p\u003e  \u003cb\u003eIncludes:\u003c\/b\u003e  \u003cul\u003e  \u003cli\u003eTrue Power™ Electrical Technology  \u003c\/li\u003e\n\u003cli\u003eTwo-line multilingual digital LCD Evolution™ controller   (English\/Spanish\/French\/Portuguese)  \u003c\/li\u003e\n\u003cli\u003eTwo transfer switch options available: 100 amp 16 circuit switch or 200 amp service rated smart switch  \u003c\/li\u003e\n\u003cli\u003eElectronic governor  \u003c\/li\u003e\n\u003cli\u003eStandard Wi-Fi® connectivity  \u003c\/li\u003e\n\u003cli\u003eSystem status \u0026amp; maintenance interval LED indicators  \u003c\/li\u003e\n\u003cli\u003eSound attenuated enclosure  \u003c\/li\u003e\n\u003cli\u003eFlexible fuel line connector  \u003c\/li\u003e\n\u003cli\u003eNatural gas or LP gas operation  \u003c\/li\u003e\n\u003cli\u003e5 Year limited warranty  \u003c\/li\u003e\n\u003cli\u003eListed and labeled for installation as close as 18 in (457  mm) to a structure    mm) to a structure.*\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e  \u003cp\u003e\u003ci\u003e*Must be located away from doors, windows, and fresh air intakes and in accordance with local codes.\u003c\/i\u003e\u003c\/p\u003e    \u003cb\u003eFeatures and Benefits:\u003c\/b\u003e  \u003cul\u003e  \u003cli\u003eEngine  \u003cul\u003e\n\u003cli\u003eGenerac G-Force design: Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.  \u003c\/li\u003e\n\u003cli\u003e“Spiny-lok” cast iron cylinder walls: Rigid construction and added durability provide long engine life.  \u003c\/li\u003e\n\u003cli\u003eElectronic ignition\/spark advance: These features combine to assure smooth, quick starting every time  \u003c\/li\u003e\n\u003cli\u003eFull pressure lubrication system: Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year\/200 hour oil change interval.  \u003c\/li\u003e\n\u003cli\u003eLow oil pressure shutdown system: Shutdown protection prevents catastrophic engine damage due to low oil.  \u003c\/li\u003e\n\u003cli\u003eEPA Certified for non-emergency applications: Allows unit to be used for demand response applications.  \u003c\/li\u003e\n\u003cli\u003eHigh temperature shutdown: Prevents damage due to overheating.  \u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eGenerator  \u003cul\u003e\n\u003cli\u003eRevolving field: Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature  generator.  \u003c\/li\u003e\n\u003cli\u003eSkewed stator: Produces a smooth output waveform for compatibility with electronic equipment.  \u003c\/li\u003e\n\u003cli\u003eDisplaced phase excitation: Maximizes motor starting capability.  \u003c\/li\u003e\n\u003cli\u003eAutomatic voltage regulation: Regulating output voltage to ±1% prevents damaging voltage spikes.  \u003c\/li\u003e\n\u003cli\u003eUL 2200 listed: For your safety.\u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eTransfer Switch (if applicable)  \u003cul\u003e\n\u003cli\u003eFully automatic: Transfers vital electrical loads to the energized source of power.  \u003c\/li\u003e\n\u003cli\u003eNEMA 3R: Can be installed inside or outside for maximum flexibility.  \u003c\/li\u003e\n\u003cli\u003eRemote mounting: Mounts near existing distribution panel for simple, low cost installation.\u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eEvaluation Controls  \u003cul\u003e\n\u003cli\u003eAUTO\/MANUAL\/OFF illuminated buttons: Select the operating mode and provide easy, at-a-glance status indication in any condition.  \u003c\/li\u003e\n\u003cli\u003eTwo-line multilingual LCD: Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences.  \u003c\/li\u003e\n\u003cli\u003eSealed, raised buttons: Smooth, weather-resistant user interface for programming and operations.  \u003c\/li\u003e\n\u003cli\u003eUtility voltage sensing: Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.  \u003c\/li\u003e\n\u003cli\u003eGenerator voltage sensing: Constantly monitors generator voltage to verify the cleanest power is delivered to the home.  \u003c\/li\u003e\n\u003cli\u003eUtility interrupt delay: Prevents nuisance startups of the engine, adjustable 2–1500 seconds from the factory default setting of  5 seconds by a qualified dealer.  \u003c\/li\u003e\n\u003cli\u003eEngine warm-up: Verifies engine is ready to assume the load. Setpoint approximately 5 seconds.  \u003c\/li\u003e\n\u003cli\u003eEngine cool-down: Allows engine to cool prior to shutdown. Setpoint approximately 1 minute.  \u003c\/li\u003e\n\u003cli\u003eProgrammable exercise: Operates engine to prevent oil seal drying and damage between power outages by running the generator  for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation, providing  flexibility and potentially lower fuel costs to the owner.   \u003c\/li\u003e\n\u003cli\u003eSmart battery charger: Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.   Compatible with lead acid and AGM-style batteries.  \u003c\/li\u003e\n\u003cli\u003eMain line circuit breaker: Protects generator from overload.  \u003c\/li\u003e\n\u003cli\u003eElectronic governor: Maintains constant 60 Hz frequency\u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eUnit  \u003cul\u003e\n\u003cli\u003eSAE weather protective enclosure: Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding  winds up to 150 mph (241 km\/h). Hinged key locking roof panel for security. Lift-out front for easy access  to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.  \u003c\/li\u003e\n\u003cli\u003eEnclosed critical grade muffler: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.  \u003c\/li\u003e\n\u003cli\u003eSmall, compact, attractive: Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.\u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eInstallation System  \u003cul\u003e\n\u003cli\u003e14 in (35.6 cm) flexible fuel line connector: Listed ANSI Z21.75\/CSA 6.27 outdoor appliance connector for the required connection to the gas supply  piping.   \u003c\/li\u003e\n\u003cli\u003eIntegral sediment trap: Meets IFGC and NFPA 54 installation requirements\u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eConnectivity  \u003cul\u003e\n\u003cli\u003eAbility to view generator status: Monitor your generator with a smartphone, tablet, or computer at any time via the Mobile Link application  for complete peace of mind.  \u003c\/li\u003e\n\u003cli\u003eAbility to view generator Exercise\/Run and Total Hours: Review the generator's complete protection profile for exercise hours and total hours.  \u003c\/li\u003e\n\u003cli\u003eAbility to view generator maintenance information: Provides maintenance information for your specific model generator when scheduled maintenance is due.  \u003c\/li\u003e\n\u003cli\u003eMonthly report with previous month’s activity: Detailed monthly reports provide historical generator information.  \u003c\/li\u003e\n\u003cli\u003eAbility to view generator battery information: Built in battery diagnostics displaying current state of the battery.  \u003c\/li\u003e\n\u003cli\u003eWeather information: Provides detailed local ambient weather conditions for generator location.  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e  \u003cb\u003eSpecifications:\u003c\/b\u003e  \u003cul\u003e  \u003cli\u003eGenerator  \u003cul\u003e  \u003cli\u003eRated maximum continuous power capacity (LP): 10,000 Watts*\u003c\/li\u003e  \u003cli\u003eRated maximum continuous power capacity (NG): 9,000 Watts*\u003c\/li\u003e  \u003cli\u003eRated voltage: 240\u003c\/li\u003e  \u003cli\u003eRated maximum continuous load current – 240 volts (LP \/ NG): 41.7 \/ 37.5\u003c\/li\u003e  \u003cli\u003eTotal Harmonic Distortion: Less than 5%  \u003c\/li\u003e\n\u003cli\u003eMain line circuit breaker: 45 Amp  \u003c\/li\u003e\n\u003cli\u003ePhase: 1  \u003c\/li\u003e\n\u003cli\u003eNumber of rotor poles: 2  \u003c\/li\u003e\n\u003cli\u003eRated AC frequency: 60 Hz  \u003c\/li\u003e\n\u003cli\u003ePower factor: 1.0  \u003c\/li\u003e\n\u003cli\u003eBattery requirement (not included): 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum  \u003c\/li\u003e\n\u003cli\u003eUnit weight (lb\/kg): 338\/153  \u003c\/li\u003e\n\u003cli\u003eDimensions (L x W x H) in \/ cm: 48 x 25 x 29 \/ 121.9 x 63.5 x 73.7  \u003c\/li\u003e\n\u003cli\u003eSound output in dB(A) at 23 ft (7 m) with generator operating at normal load**: 61   \u003c\/li\u003e\n\u003cli\u003eSound output in dB(A) at 23 ft (7 m) with generator in Quiet-Test™ low-speed exercise mode**: 57   \u003c\/li\u003e\n\u003cli\u003eExercise duration: 5 min\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli\u003eEngine  \u003cul\u003e  \u003cli\u003eEngine type: GENERAC G-Force 400 Series\u003c\/li\u003e  \u003cli\u003eNumber of cylinders: 1\u003c\/li\u003e  \u003cli\u003eDisplacement: 460 cc\u003c\/li\u003e  \u003cli\u003eCylinder block: Aluminum w\/ cast iron sleeve\u003c\/li\u003e  \u003cli\u003eValve arrangement: Overhead valve\u003c\/li\u003e  \u003cli\u003eLifter Type: Solid  \u003c\/li\u003e\n\u003cli\u003eIgnition system: Solid-state w\/ magneto\u003c\/li\u003e  \u003cli\u003eGovernor system: Electronic\u003c\/li\u003e  \u003cli\u003eCompression ratio: 9:5:1\u003c\/li\u003e  \u003cli\u003eStarter: 12 VDC  \u003c\/li\u003e\n\u003cli\u003eOil capacity including filter: Approx. 1.1 qt\/1.0 L\u003c\/li\u003e  \u003cli\u003eOperating rpm: 3,600\u003c\/li\u003e  \u003cli\u003eFuel consumption:\u003c\/li\u003e  \u003cli\u003eNatural Gas ft³\/hr (m³\/hr)  \u003cul\u003e  \u003cli\u003e1\/2 Load: 101 (2.86)\u003c\/li\u003e  \u003cli\u003eFull Load: 127 (3.60)\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli\u003eLiquid Propane ft3\/hr (gal\/hr) [L\/hr]  \u003cul\u003e  \u003cli\u003e1\/2 Load: 36 (0.97) [3.66]\u003c\/li\u003e  \u003cli\u003eFull Load: 54 (1.48) [5.62]\u003c\/li\u003e  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e  \u003cp\u003e\u003ci\u003e\u003cb\u003eNote: Fuel pipe must be sized for full load.\u003c\/b\u003e Required fuel pressure to generator fuel inlet at all load ranges -3.5–7.0 in water column (0.87–1.74 kPa) for NG, 10–12 in water column (2.49–2.99 kPa) for LP gas. For BTU content, multiply ft3\/hr x 2500 (LP) or ft3\/hr x 1000 (NG). For Megajoule content, multiply m³\/hr x 93.15 (LP) or m³\/hr x 37.26 (NG).\u003c\/i\u003e  \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e  \u003cul\u003e  \u003cli\u003eControls  \u003cul\u003e  \u003cli\u003eTwo-line plain text multilingual LCD: Simple user interface for easy operation.\u003c\/li\u003e  \u003cli\u003eMode buttons:  \u003cul\u003e  \u003cli\u003eAUTO:Automatic start on utility failure. Weekly, Bi-Weekly, or Monthly selectable exerciser.\u003c\/li\u003e  \u003cli\u003eMANUAL\/TEST (start): Start with starter control, unit stays on. If utility fails, transfer to load takes place.\u003c\/li\u003e  \u003cli\u003eOFF: Stops unit. Power is removed. Control and charger still operate.\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli\u003eReady to Run\/Maintenance messages Standard  \u003c\/li\u003e\n\u003cli\u003eEngine run hours indication: Standard  \u003c\/li\u003e\n\u003cli\u003eProgrammable start delay between 2–1500 seconds: Standard (programmable by dealer only)  \u003c\/li\u003e\n\u003cli\u003eUtility voltage loss\/Return to utility adjustable (brownout setting): From 140-171 V \/ 190-216 V  \u003c\/li\u003e\n\u003cli\u003eFuture set capable exerciser\/Exercise set error warning Standard  \u003c\/li\u003e\n\u003cli\u003eRun\/Alarm\/Maintenance logs: 50 events each  \u003c\/li\u003e\n\u003cli\u003eEngine start sequence: Cyclic cranking: 16 sec on, 7 sec rest (90 sec maximum duration).  \u003c\/li\u003e\n\u003cli\u003eStarter lock-out: Starter cannot re-engage until 5 sec after engine has stopped.  \u003c\/li\u003e\n\u003cli\u003eSmart Battery Charger: Standard  \u003c\/li\u003e\n\u003cli\u003eCharger Fault\/Missing AC Warning Standard  \u003c\/li\u003e\n\u003cli\u003eLow Battery\/Battery Problem Protection and Battery Condition Indication: Standard  \u003c\/li\u003e\n\u003cli\u003eAutomatic Voltage Regulation with Over and Under Voltage Protection: Standard  \u003c\/li\u003e\n\u003cli\u003eUnder-Frequency\/Overload\/Stepper Overcurrent Protection: Standard  \u003c\/li\u003e\n\u003cli\u003eSafety Fused\/Fuse Problem Protection: Standard  \u003c\/li\u003e\n\u003cli\u003eAutomatic Low Oil Pressure\/High Oil Temperature Shutdown: Standard  \u003c\/li\u003e\n\u003cli\u003eOvercrank\/Overspeed (@ 72 Hz)\/rpm Sense Loss Shutdown: Standard  \u003c\/li\u003e\n\u003cli\u003eHigh Engine Temperature Shutdown: Standard  \u003c\/li\u003e\n\u003cli\u003eInternal Fault\/Incorrect Wiring Protection: Standard  \u003c\/li\u003e\n\u003cli\u003eCommon External Fault Capability: Standard  \u003c\/li\u003e\n\u003cli\u003eField Upgradable Firmware: Standard  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e  \u003cp\u003e\u003ci\u003eRating definitions - Optional Standby: Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046, UL2200, and DIN6271).\u003cbr\u003e  \u003cbr\u003e* Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU\/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C).\u003cbr\u003e    \u003cbr\u003e**Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.\u003c\/i\u003e  \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e  \u003cb\u003eLimited Circuit Switch Features:\u003c\/b\u003e  \u003cul\u003e  \u003cli\u003eElectrically operated, mechanically-held contacts for fast, positive connections.  \u003c\/li\u003e\n\u003cli\u003eRated for all classes of load, 100% equipment rated, both inductive and resistive.  \u003c\/li\u003e\n\u003cli\u003e2-pole, 240 VAC contactors.  \u003c\/li\u003e\n\u003cli\u003e30 millisecond transfer time.  \u003c\/li\u003e\n\u003cli\u003eDual coil design  \u003c\/li\u003e\n\u003cli\u003eRated for both copper and aluminum conductors.  \u003c\/li\u003e\n\u003cli\u003eMain contacts are silver plated or silver alloy to resist welding and sticking.  \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL 3R aluminum outdoor enclosure allows for indoor or outdoor   mounting flexibility.  \u003c\/li\u003e\n\u003cli\u003eMulti listed for use with 1\" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton, and Square D for the most flexible and cost effective install.  \u003c\/li\u003e\n\u003cli\u003eFlush mountable.\u003c\/li\u003e  \u003c\/ul\u003e  \u003cb\u003eLimited Circuit Switch Specifications:\u003c\/b\u003e  \u003cul\u003e  \u003cli\u003eNo. of poles: 2  \u003c\/li\u003e\n\u003cli\u003eCurrent rating (amps): 100  \u003c\/li\u003e\n\u003cli\u003eVoltage rating (VAC): 120\/240 1Ø  \u003c\/li\u003e\n\u003cli\u003eUtility voltage monitor (fixed)*  \u003cul\u003e\n\u003cli\u003e—Pick-up: 80%  \u003c\/li\u003e\n\u003cli\u003e—Dropout: 65%\u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eReturn to utility*: Approx. 15 sec  \u003c\/li\u003e\n\u003cli\u003eExerciser weekly for 5 minutes*: Standard  \u003c\/li\u003e\n\u003cli\u003eETL or UL Listed: Standard  \u003c\/li\u003e\n\u003cli\u003eTotal circuits available: 24  \u003c\/li\u003e\n\u003cli\u003eTandem breaker capability: 8 tandems  \u003c\/li\u003e\n\u003cli\u003eCircuit breaker protected  \u003cul\u003e\u003cli\u003eAvailable RMS symmetrical fault current @ 250 V 10,000\u003c\/li\u003e\u003c\/ul\u003e  \u003ci\u003e*Function of controller\u003c\/i\u003e  \u003cbr\u003e  \u003ci\u003eExercise can be set to weekly or monthly\u003c\/i\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e    \u003cb\u003eInfo and Guides:\u003c\/b\u003e  \u003cp\u003e  \u003ca target=\"_blank\" href=\"\/images\/Generac\/Manuals\/g-10-22kw-60hz-standby-generator-owners-manual-en.pdf\"\u003eClick Here for Owner Manual\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e  \u003ca target=\"_blank\" href=\"\/images\/Generac\/Manuals\/10-18kw-guardian-standby-generator-specsheet-en.pdf\"\u003eClick Here for Spec Sheet*\u003c\/a\u003e\u003cbr\u003e  \u003cb\u003e*Spec sheet might include optional accessories not included with this purchase\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e    \u003cb\u003ePlease Note the List of Items Below That Are Non-Returnable:\u003c\/b\u003e  \u003c\/p\u003e\u003cul\u003e  \u003cli\u003eSpecial Order items including but not limited to whole house or stationary generators  \u003c\/li\u003e\n\u003cli\u003eWhole goods and attachments, literature, engines, pumps, short blocks, electrical parts, gaskets, liquids, chemicals, sprays  \u003c\/li\u003e\n\u003cli\u003eItems with damaged or non-original packaging  \u003c\/li\u003e\n\u003cli\u003eInstalled, used or damaged items  \u003c\/li\u003e\n\u003c\/ul\u003e  \u003cb\u003eCancellation Policy Summary\u003c\/b\u003e  \u003cul\u003e  \u003cli\u003eAir-Cooled Product \u0026amp; short lead time Liquid-Cooled Product (60kW and smaller)\u003cul\u003e  \u003cli\u003eOrders cancelled within 6 weeks of original ship date – 10% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eShipped Orders – 15% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eOrders cancelled within 72 hours (calendar)  of receipt – NO FEE\u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eLong lead time Liquid-Cooled Product (80kW to 150kW)\u003cul\u003e  \u003cli\u003eOrders cancelled within 12 weeks of original ship date – 15% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eShipped Orders – NO CANCELLATION ALLOWED  \u003c\/li\u003e\n\u003cli\u003eOrders cancelled within 72hrs (calendar)  of order receipt – NO FEE\u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eProtector Plus \/ Configured Product\u003cul\u003e  \u003cli\u003eCancellation within 20 weeks of original ship date – 10% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eCancellation within 18 weeks of original ship date – 20% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eCancellation within 16 weeks of original ship date – 30% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eCancellation within 15 weeks of original ship date – 40% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eOrders cancelled within 72hrs (calendar) of order receipt – NO FEE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Generac","offers":[{"title":"Default Title","offer_id":47902681432222,"sku":"ET17412","price":4189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/8990\/3518\/files\/ET17412-Generac-Guardian-10-9-kWAir-Cooled-Standby-Generator-Aluminum-Enclosure-w-16-Circuit-Transfer-Switch-WiFi-Enabled-w-free-MobileLink-7172-md.jpg?v=1782415860","url":"https:\/\/titantoolsdirect.com\/products\/generac-10kw-air-cooled-home-standby-with-16-circuit-100-amp-transfer-switch-7172","provider":"Titan Tools Direct","version":"1.0","type":"link"}