{"product_id":"generac-guardian-14kw-standby-generator-with-mobile-link-cellular-monitoring-7258","title":"Generac Guardian 14kW Standby Generator with Mobile Link Cellular Monitoring - 7258","description":"Generac Guardian 14kW Standby Generator with Mobile Link Cellular Monitoring  \u003cbr\u003e\u003cbr\u003e  Model Number: 7258  \u003cbr\u003e  \u003cp\u003eThe Generac Guardian 14kW Standby Generator delivers reliable backup power with advanced monitoring features to keep your home protected and comfortable. Designed with extended service intervals, it minimizes maintenance needs so you can focus on enjoying uninterrupted peace of mind.    \u003c\/p\u003e\u003cp\u003eEquipped with remote diagnostics, the generator continuously tracks performance and identifies potential issues before they become costly problems. Its built?in cellular connectivity integrates with Mobile Link™, allowing you to monitor and control your generator from anywhere. With a premium Mobile Link™ subscription, you’ll receive real?time updates and maintenance alerts directly to your device.    \u003c\/p\u003e\u003cp\u003eAdditional smart features include oil level sensors for readiness assurance, enhanced cold?start capability for reliable operation in low temperatures, and a sloped roof with rear air intake to reduce snow and ice intrusion. The Guardian 14kW is also compatible with ecobee thermostats and Generac PWRcell battery systems, enabling seamless energy management across your home.    \u003c\/p\u003e\u003cp\u003eBacked by a 5?year limited warranty and over 65 years of Generac innovation, this generator combines durability, convenience, and cutting?edge technology to deliver dependable standby power when you need it most.  \u003c\/p\u003e  \u003cb\u003eFeatures:\u003c\/b\u003e  \u003cul\u003e  \u003cli\u003eInnovative Enginer Design \u0026amp; Rigorous Testing are at the heart of Generac’s success in providing the most reliable generators possible. Generac’s G-Force engine lineup offers added peace of mind and reliability for when it’s needed the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions.  \u003c\/li\u003e\n\u003cli\u003eTrue Power Electrical technology: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems.  \u003c\/li\u003e\n\u003cli\u003eTest Criteria  \u003cul\u003e  \u003cli\u003ePrototype tested  \u003c\/li\u003e\n\u003cli\u003eSystem torsional tested  \u003c\/li\u003e\n\u003cli\u003eNema MG1-22 Evaluation  \u003c\/li\u003e\n\u003cli\u003eMotor Starting Ability  \u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eMobile Link Connectivity: Standard with the Generac Air-Cooled Standby Generator home standby generators, Mobile Link Cellular allows users to monitor the status of their generator from anywhere using a smartphone, tablet, or PC. Easily access real-time operating status, maintenance alerts, and generator readiness. Users can also connect their account to an authorized service dealer for proactive support and streamlined service. With Mobile Link, users can see their generator is ready before the next power outage.  \u003c\/li\u003e\n\u003cli\u003eSolid-State Voltage Regulation: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides  optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%.  \u003c\/li\u003e\n\u003cli\u003eSingle Source Service Response: from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.  \u003c\/li\u003e\n\u003cli\u003eGenerac Transfer Switches:  Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility    \u003c\/li\u003e\n\u003c\/ul\u003e  \u003cb\u003eIncludes:\u003c\/b\u003e  \u003cul\u003e  \u003cli\u003eCellular connectivity standard, with Wi-Fi™ and Bluetooth™ capabilities  \u003c\/li\u003e\n\u003cli\u003eElectronic fuel and ignition control (EFIC)  \u003c\/li\u003e\n\u003cli\u003eHydraulic lifters  \u003c\/li\u003e\n\u003cli\u003eSmartExercise Technology  \u003c\/li\u003e\n\u003cli\u003eTruePower™Electrical Technology  \u003c\/li\u003e\n\u003cli\u003ePowerZone™200Controller  \u003c\/li\u003e\n\u003cli\u003eOil level sensor  \u003c\/li\u003e\n\u003cli\u003e200Ampservice rated transfer switch in bundled models  \u003c\/li\u003e\n\u003cli\u003eElectronic governor  \u003c\/li\u003e\n\u003cli\u003eSystemstatus \u0026amp; maintenance interval LED indicators  \u003c\/li\u003e\n\u003cli\u003eSoundattenuated enclosure  \u003c\/li\u003e\n\u003cli\u003eNatural gas or LP gas operation  \u003c\/li\u003e\n\u003cli\u003e5Year limited warranty, generator and transfer switch  \u003c\/li\u003e\n\u003cli\u003eListed and labeled by the Southwest Research Institute allowing installation  as close as 18 in (457 mm) to a structure.*  \u003cp\u003e\u003ci\u003e*Must be located away from doors, windows, and fresh air intakes and in  accordance with local codes.\u003c\/i\u003e\u003c\/p\u003e  \u003c\/li\u003e\n\u003c\/ul\u003e  \u003cb\u003eSpecifications:\u003c\/b\u003e  \u003cul\u003e  \u003cli\u003eGenerator  \u003cul\u003e  \u003cli\u003eRated maximum continuous power capacity (LP): 14kW*\u003c\/li\u003e  \u003cli\u003eRated maximum continuous power capacity (NG): 14kW*\u003c\/li\u003e  \u003cli\u003eRated voltage: 240\u003c\/li\u003e  \u003cli\u003eRated maximum continuous load current – 240 volts (LP \/ NG): 58 \/ 58\u003c\/li\u003e  \u003cli\u003eTotal Harmonic Distortion: Less than 5%  \u003c\/li\u003e\n\u003cli\u003eMain line circuit breaker: 45 Amp  \u003c\/li\u003e\n\u003cli\u003ePhase: 1  \u003c\/li\u003e\n\u003cli\u003eNumber of rotor poles: 2  \u003c\/li\u003e\n\u003cli\u003eRated AC frequency: 60 Hz  \u003c\/li\u003e\n\u003cli\u003ePower factor: 1.0  \u003c\/li\u003e\n\u003cli\u003eBattery requirement (not included):  12volts,AGMPowersportBatteryGroupBTX20 310CCA minimum  \u003c\/li\u003e\n\u003cli\u003eUnit weight (lb\/kg): 319\/177  \u003c\/li\u003e\n\u003cli\u003eDimensions (L x W x H) in \/ cm:  46.4x26.3x30.7\/117.9x66.8x77.9  \u003c\/li\u003e\n\u003cli\u003eSound output in dB(A) at 23 ft (7 m) with generator operating at normal load**: 65  \u003c\/li\u003e\n\u003cli\u003eSound output in dB(A) at 23 ft (7 m) with generator in Quie-Test™ low-speed exercise mode**: 55   \u003c\/li\u003e\n\u003cli\u003eExercise duration: Adjustable5-20min(5minfactorydefault)\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli\u003eEngine  \u003cul\u003e  \u003cli\u003eEngine type: GENERAC G-Force 800 Series\u003c\/li\u003e  \u003cli\u003eNumber of cylinders: 2\u003c\/li\u003e  \u003cli\u003eDisplacement: 817 cc\u003c\/li\u003e  \u003cli\u003eCylinder block: Aluminum w\/ cast iron sleeve\u003c\/li\u003e  \u003cli\u003eValve arrangement: Overhead valve\u003c\/li\u003e  \u003cli\u003eLifter Type: Hydraulic  \u003c\/li\u003e\n\u003cli\u003eIgnition system: Solid-state\u003c\/li\u003e  \u003cli\u003eGovernor system: Electronic\u003c\/li\u003e  \u003cli\u003eCompression ratio: 9:5:1\u003c\/li\u003e  \u003cli\u003eStarter: 12 VDC  \u003c\/li\u003e\n\u003cli\u003eOil capacity including filter:  Approx.2.5qt\/2.4L\u003c\/li\u003e  \u003cli\u003eOperating rpm: 3,600\u003c\/li\u003e  \u003cli\u003eFuel consumption:\u003c\/li\u003e  \u003cli\u003eNatural Gas ft³\/hr (m³\/hr)  \u003cul\u003e  \u003cli\u003e1\/2 Load: 189(5.35)\u003c\/li\u003e  \u003cli\u003eFull Load: 243(6.89\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli\u003eLiquid Propane ft3\/hr (gal\/hr) [L\/hr]  \u003cul\u003e  \u003cli\u003e1\/2 Load: 63(1.76)[6.66]\u003c\/li\u003e  \u003cli\u003eFull Load: 106(2.92)[11.03]\u003c\/li\u003e  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e  \u003cp\u003e\u003ci\u003e\u003cb\u003eNote: Fuel pipe must be sized for full load.\u003c\/b\u003e Required fuel pressure to generator fuel inlet at all load ranges -3.5–7.0 in water column (0.87–1.74 kPa) for NG, 10–12 in water column (2.49–2.99 kPa) for LP gas. For BTU content, multiply ft3\/hr x 2500 (LP) or ft3\/hr x 1000 (NG). For Megajoule content, multiply m³\/hr x 93.15 (LP) or m³\/hr x 37.26 (NG).\u003c\/i\u003e  \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e  \u003cul\u003e  \u003cli\u003eControls  \u003cul\u003e  \u003cli\u003eTwo-line plain text multilingual LCD: Simple user interface for easy operation.\u003c\/li\u003e  \u003cli\u003eMode buttons:  \u003cul\u003e  \u003cli\u003eAUTO:Automatic start on utility failure. Programmable exerciser.  \u003c\/li\u003e  \u003cli\u003eMANUAL\/TEST (start): Start with starter control, unit stays on. If utility fails, transfer to load takes place.\u003c\/li\u003e  \u003cli\u003eOFF: Stops unit. Power is removed. Control and charger still operate.\u003c\/li\u003e  \u003c\/ul\u003e  \u003c\/li\u003e  \u003cli\u003eReady to Run\/Maintenance messages: Standard  \u003c\/li\u003e\n\u003cli\u003eEngine run hours indication: Standard  \u003c\/li\u003e\n\u003cli\u003eProgrammable start delay between 2–1500 seconds: Standard   \u003c\/li\u003e\n\u003cli\u003eUtility voltage loss\/Return to utility adjustable (brownout setting): From 140-171 V \/ 190-216 V  \u003c\/li\u003e\n\u003cli\u003eFuture set capable exerciser\/Exercise set error warning Standard  \u003c\/li\u003e\n\u003cli\u003eRun\/Alarm\/Maintenance logs: 50 events each  \u003c\/li\u003e\n\u003cli\u003eEngine start sequence: Cyclic cranking: 16 sec on, 7 sec rest (90 sec maximum duration).  \u003c\/li\u003e\n\u003cli\u003eStarter lock-out: Starter cannot re-engage until 5 sec after engine has stopped.  \u003c\/li\u003e\n\u003cli\u003eSmart Battery Charger: Standard  \u003c\/li\u003e\n\u003cli\u003eCharger Fault\/Missing AC Warning: Standard  \u003c\/li\u003e\n\u003cli\u003eLow Battery\/Battery Problem Protection and Battery Condition Indication: Standard  \u003c\/li\u003e\n\u003cli\u003eAutomatic Voltage Regulation with Over and Under Voltage Protection: Standard  \u003c\/li\u003e\n\u003cli\u003eUnder-Frequency\/Overload\/Stepper Overcurrent Protection: Standard  \u003c\/li\u003e\n\u003cli\u003eSafety Fused\/Fuse Problem Protection: Standard  \u003c\/li\u003e\n\u003cli\u003eAutomatic Low Oil Pressure\/High Oil Temperature Shutdown: Standard  \u003c\/li\u003e\n\u003cli\u003eOvercrank\/Overspeed (@ 72 Hz)\/rpm Sense Loss Shutdown: Standard  \u003c\/li\u003e\n\u003cli\u003eHigh Engine Temperature Shutdown: Standard  \u003c\/li\u003e\n\u003cli\u003eInternal Fault\/Incorrect Wiring Protection: Standard  \u003c\/li\u003e\n\u003cli\u003eCommon External Fault Capability: Standard  \u003c\/li\u003e\n\u003cli\u003eField Upgradable Firmware: Standard  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e  \u003cp\u003e\u003ci\u003eRating definitions - Optional Standby: Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046, UL2200, and DIN6271).\u003cbr\u003e  \u003cbr\u003e* Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU\/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C).\u003cbr\u003e    \u003cbr\u003e**Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.\u003c\/i\u003e  \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e    \u003cb\u003eInfo and Guides:\u003c\/b\u003e  \u003cp\u003e  \u003ca target=\"_blank\" href=\"\/images\/Generac\/Manuals\/A0004332577.pdf\"\u003eClick Here for Owner Manual\u003c\/a\u003e\u003cbr\u003e  \u003c\/p\u003e\u003cp\u003e  \u003ca target=\"_blank\" href=\"\/images\/Generac\/Manuals\/A0005151081.pdf\"\u003eClick Here for Spec Sheet*\u003c\/a\u003e\u003cbr\u003e  \u003cb\u003e*Spec sheet might include optional accessories not included with this purchase\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e    \u003cb\u003ePlease Note the List of Items Below That Are Non-Returnable:\u003c\/b\u003e  \u003c\/p\u003e\u003cul\u003e  \u003cli\u003eSpecial Order items including but not limited to whole house or stationary generators  \u003c\/li\u003e\n\u003cli\u003eWhole goods and attachments, literature, engines, pumps, short blocks, electrical parts, gaskets, liquids, chemicals, sprays  \u003c\/li\u003e\n\u003cli\u003eItems with damaged or non-original packaging  \u003c\/li\u003e\n\u003cli\u003eInstalled, used or damaged items  \u003c\/li\u003e\n\u003c\/ul\u003e  \u003cb\u003eCancellation Policy Summary\u003c\/b\u003e  \u003cul\u003e  \u003cli\u003eAir-Cooled Product \u0026amp; short lead time Liquid-Cooled Product (60kW and smaller)\u003cul\u003e  \u003cli\u003eOrders cancelled within 6 weeks of original ship date – 10% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eShipped Orders – 15% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eOrders cancelled within 72 hours (calendar)  of receipt – NO FEE\u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eLong lead time Liquid-Cooled Product (80kW to 150kW)\u003cul\u003e  \u003cli\u003eOrders cancelled within 12 weeks of original ship date – 15% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eShipped Orders – NO CANCELLATION ALLOWED  \u003c\/li\u003e\n\u003cli\u003eOrders cancelled within 72hrs (calendar)  of order receipt – NO FEE\u003c\/li\u003e\n\u003c\/ul\u003e  \u003c\/li\u003e\n\u003cli\u003eProtector Plus \/ Configured Product\u003cul\u003e  \u003cli\u003eCancellation within 20 weeks of original ship date – 10% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eCancellation within 18 weeks of original ship date – 20% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eCancellation within 16 weeks of original ship date – 30% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eCancellation within 15 weeks of original ship date – 40% CANCELLATION FEE  \u003c\/li\u003e\n\u003cli\u003eOrders cancelled within 72hrs (calendar) of order receipt – NO FEE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Generac","offers":[{"title":"Default Title","offer_id":47902697619614,"sku":"ET19555","price":4889.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/8990\/3518\/files\/ET19555-Generac-Guardian-14kW-Standby-Generator-with-Mobile-Link-Cellular-Monitoring-7258-md.jpg?v=1782416037","url":"https:\/\/titantoolsdirect.com\/products\/generac-guardian-14kw-standby-generator-with-mobile-link-cellular-monitoring-7258","provider":"Titan Tools Direct","version":"1.0","type":"link"}