{"product_id":"radiodetection-rd1100-ground-penetrating-radar","title":"Radiodetection RD1100 Ground Penetrating Radar","description":"\u003ch1 data-section-id=\"5jaxpm\" data-start=\"0\" data-end=\"64\" class=\"PDq2pG_selectionAnchorContainer\"\u003eRadiodetection RD1100 Ground Penetrating Radar Utility Locator\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"66\" data-end=\"122\"\u003e\u003cstrong data-start=\"66\" data-end=\"83\"\u003eModel Number:\u003c\/strong\u003e RD1100\u003cbr data-start=\"90\" data-end=\"93\"\u003e\u003cstrong data-start=\"93\" data-end=\"105\"\u003ePricing:\u003c\/strong\u003e Call for Pricing\u003c\/p\u003e\n\u003ch2 data-section-id=\"lgf4ba\" data-start=\"124\" data-end=\"161\"\u003eFREE On-Site RD1100 Demonstrations\u003c\/h2\u003e\n\u003cp data-start=\"163\" data-end=\"278\"\u003eTitan Tools Direct offers \u003cstrong data-start=\"189\" data-end=\"242\"\u003eFREE on-site Radiodetection RD1100 demonstrations\u003c\/strong\u003e for qualified customers located in:\u003c\/p\u003e\n\u003cp data-start=\"280\" data-end=\"441\"\u003e\u003cstrong data-start=\"280\" data-end=\"441\"\u003eVirginia, West Virginia, Maryland, Delaware, New Jersey, Pennsylvania, Rhode Island, New York, Connecticut, Massachusetts, Vermont, New Hampshire, and Maine.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"443\" data-end=\"646\"\u003eSchedule an on-site demonstration to see how the RD1100 can help identify metallic and non-metallic utilities, undocumented infrastructure, disturbed soil, and buried structures before excavation begins.\u003c\/p\u003e\n\u003ch2 data-section-id=\"apffzw\" data-start=\"648\" data-end=\"666\"\u003eRequest Pricing\u003c\/h2\u003e\n\u003cp data-start=\"668\" data-end=\"907\"\u003eThe \u003cstrong data-start=\"672\" data-end=\"722\"\u003eRadiodetection RD1100 Ground Penetrating Radar\u003c\/strong\u003e is a professional subsurface locating system designed to detect buried utilities and structures that may not be identifiable using traditional electromagnetic locating equipment alone.\u003c\/p\u003e\n\u003cp data-start=\"909\" data-end=\"986\"\u003eFor current pricing, availability, demonstrations, and purchasing assistance:\u003c\/p\u003e\n\u003cp data-start=\"988\" data-end=\"1058\"\u003e\u003cstrong data-start=\"988\" data-end=\"1005\"\u003eCall or Text:\u003c\/strong\u003e 832-727-9353\u003cbr data-start=\"1018\" data-end=\"1021\"\u003e\u003cstrong data-start=\"1021\" data-end=\"1031\"\u003eEmail:\u003c\/strong\u003e \u003ca data-start=\"1032\" data-end=\"1058\" class=\"decorated-link cursor-pointer\" rel=\"noopener\"\u003eSales@TitanToolsDirect.com\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"1060\" data-end=\"1079\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"1081\" data-end=\"1479\"\u003eThe \u003cstrong data-start=\"1085\" data-end=\"1151\"\u003eRadiodetection RD1100 Ground Penetrating Radar, or GPR, system\u003c\/strong\u003e provides a rapid and non-destructive method for locating buried utilities and subsurface objects. Using radio waves, the RD1100 produces real-time subsurface images that help utility locating professionals, municipalities, contractors, engineers, and excavation teams better understand what is located below the ground surface.\u003c\/p\u003e\n\u003cp data-start=\"1481\" data-end=\"1717\"\u003eThe RD1100 offers a practical balance of \u003cstrong data-start=\"1522\" data-end=\"1565\"\u003edepth penetration and target resolution\u003c\/strong\u003e. Depending on soil conditions, target characteristics, and site conditions, the system can detect objects at depths of up to approximately \u003cstrong data-start=\"1705\" data-end=\"1716\"\u003e27 feet\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1719\" data-end=\"2181\"\u003eUnlike electromagnetic pipe and cable locators, which generally depend on a conductive utility, accessible connection point, or functioning tracer wire, GPR can help identify both \u003cstrong data-start=\"1899\" data-end=\"1936\"\u003emetallic and non-metallic targets\u003c\/strong\u003e. This makes the RD1100 especially useful for locating PVC and other non-conductive utilities, undocumented infrastructure, broken tracer-wire systems, buried structures, and areas of disturbed soil associated with previous utility installation.\u003c\/p\u003e\n\u003cp data-start=\"2183\" data-end=\"2440\"\u003eGPR does not replace electromagnetic locating in every application. Instead, the RD1100 complements traditional EM locating methods by providing an additional layer of subsurface information and helping operators develop a more complete underground picture.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hs3q9g\" data-start=\"2442\" data-end=\"2472\"\u003eWhat Can the RD1100 Detect?\u003c\/h2\u003e\n\u003cp data-start=\"2474\" data-end=\"2558\"\u003eThe Radiodetection RD1100 is designed to help identify subsurface targets including:\u003c\/p\u003e\n\u003cul data-start=\"2560\" data-end=\"2976\"\u003e\n\u003cli data-section-id=\"8xy86x\" data-start=\"2560\" data-end=\"2580\"\u003eMetallic utilities\u003c\/li\u003e\n\u003cli data-section-id=\"1veyrp7\" data-start=\"2581\" data-end=\"2605\"\u003eNon-metallic utilities\u003c\/li\u003e\n\u003cli data-section-id=\"vobias\" data-start=\"2606\" data-end=\"2652\"\u003eUtilities with broken or failed tracer wires\u003c\/li\u003e\n\u003cli data-section-id=\"9owv40\" data-start=\"2653\" data-end=\"2681\"\u003eUndocumented utility lines\u003c\/li\u003e\n\u003cli data-section-id=\"1fh6l93\" data-start=\"2682\" data-end=\"2719\"\u003ePVC and other non-conductive piping\u003c\/li\u003e\n\u003cli data-section-id=\"ea8sqt\" data-start=\"2720\" data-end=\"2752\"\u003eUnderground electrical conduit\u003c\/li\u003e\n\u003cli data-section-id=\"swlk1r\" data-start=\"2753\" data-end=\"2780\"\u003eUnderground storage tanks\u003c\/li\u003e\n\u003cli data-section-id=\"1sq1bau\" data-start=\"2781\" data-end=\"2794\"\u003eSplice pits\u003c\/li\u003e\n\u003cli data-section-id=\"1ljm5ei\" data-start=\"2795\" data-end=\"2812\"\u003eBuried manholes\u003c\/li\u003e\n\u003cli data-section-id=\"x13i60\" data-start=\"2813\" data-end=\"2823\"\u003eTrenches\u003c\/li\u003e\n\u003cli data-section-id=\"17r2u5o\" data-start=\"2824\" data-end=\"2871\"\u003eDisturbed soil associated with utility burial\u003c\/li\u003e\n\u003cli data-section-id=\"i5pz4n\" data-start=\"2872\" data-end=\"2889\"\u003eOld foundations\u003c\/li\u003e\n\u003cli data-section-id=\"oltx87\" data-start=\"2890\" data-end=\"2917\"\u003eBuried structural remains\u003c\/li\u003e\n\u003cli data-section-id=\"7y6695\" data-start=\"2918\" data-end=\"2933\"\u003eConcrete pads\u003c\/li\u003e\n\u003cli data-section-id=\"9kjen5\" data-start=\"2934\" data-end=\"2942\"\u003eVaults\u003c\/li\u003e\n\u003cli data-section-id=\"1psbo6j\" data-start=\"2943\" data-end=\"2976\"\u003eUnexpected excavation obstacles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2978\" data-end=\"3140\"\u003eDetection performance depends on soil composition, moisture, target depth, target size, target material, and the contrast between the target and surrounding soil.\u003c\/p\u003e\n\u003ch2 data-section-id=\"sccsjl\" data-start=\"3142\" data-end=\"3193\"\u003eCompare GPR and Electromagnetic Utility Locating\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3195\" data-end=\"4673\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3195\" data-end=\"3284\"\u003e\n\u003ctr data-start=\"3195\" data-end=\"3284\"\u003e\n\u003cth data-start=\"3195\" data-end=\"3217\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eLocating Capability\u003c\/th\u003e\n\u003cth data-start=\"3217\" data-end=\"3255\" data-col-size=\"md\" class=\"last:pe-10\"\u003eTraditional Electromagnetic Locator\u003c\/th\u003e\n\u003cth data-start=\"3255\" data-end=\"3284\" data-col-size=\"md\" class=\"last:pe-10\"\u003eRadiodetection RD1100 GPR\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3299\" data-end=\"4673\"\u003e\n\u003ctr data-start=\"3299\" data-end=\"3445\"\u003e\n\u003ctd data-start=\"3299\" data-end=\"3320\" data-col-size=\"sm\"\u003eMetallic Utilities\u003c\/td\u003e\n\u003ctd data-start=\"3320\" data-end=\"3384\" data-col-size=\"md\"\u003eExcellent when a conductive signal can be applied or detected\u003c\/td\u003e\n\u003ctd data-start=\"3384\" data-end=\"3445\" data-col-size=\"md\"\u003eDetectable when sufficient subsurface contrast is present\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3446\" data-end=\"3613\"\u003e\n\u003ctd data-start=\"3446\" data-end=\"3471\" data-col-size=\"sm\"\u003eNon-Metallic Utilities\u003c\/td\u003e\n\u003ctd data-start=\"3471\" data-end=\"3534\" data-col-size=\"md\"\u003eGenerally requires tracer wire, sonde, or conductive element\u003c\/td\u003e\n\u003ctd data-start=\"3534\" data-end=\"3613\" data-col-size=\"md\"\u003eCan detect non-metallic utilities directly under suitable ground conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3614\" data-end=\"3751\"\u003e\n\u003ctd data-start=\"3614\" data-end=\"3625\" data-col-size=\"sm\"\u003ePVC Pipe\u003c\/td\u003e\n\u003ctd data-start=\"3625\" data-end=\"3675\" data-col-size=\"md\"\u003eRequires tracer wire or another locating method\u003c\/td\u003e\n\u003ctd data-start=\"3675\" data-end=\"3751\" data-col-size=\"md\"\u003eCan identify PVC and other non-conductive pipe under suitable conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3752\" data-end=\"3880\"\u003e\n\u003ctd data-start=\"3752\" data-end=\"3773\" data-col-size=\"sm\"\u003eBroken Tracer Wire\u003c\/td\u003e\n\u003ctd data-start=\"3773\" data-end=\"3814\" data-col-size=\"md\"\u003eMay prevent continuous utility tracing\u003c\/td\u003e\n\u003ctd data-start=\"3814\" data-end=\"3880\" data-col-size=\"md\"\u003eCan help locate the utility without relying on the tracer wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3881\" data-end=\"4017\"\u003e\n\u003ctd data-start=\"3881\" data-end=\"3906\" data-col-size=\"sm\"\u003eUndocumented Utilities\u003c\/td\u003e\n\u003ctd data-start=\"3906\" data-end=\"3951\" data-col-size=\"md\"\u003eLimited when no signal source is available\u003c\/td\u003e\n\u003ctd data-start=\"3951\" data-end=\"4017\" data-col-size=\"md\"\u003eCan reveal subsurface targets without existing utility records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4018\" data-end=\"4139\"\u003e\n\u003ctd data-start=\"4018\" data-end=\"4046\" data-col-size=\"sm\"\u003eUnderground Storage Tanks\u003c\/td\u003e\n\u003ctd data-start=\"4046\" data-end=\"4077\" data-col-size=\"md\"\u003eLimited and target-dependent\u003c\/td\u003e\n\u003ctd data-start=\"4077\" data-end=\"4139\" data-col-size=\"md\"\u003eCan identify buried tanks and related subsurface anomalies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4140\" data-end=\"4285\"\u003e\n\u003ctd data-start=\"4140\" data-end=\"4176\" data-col-size=\"sm\"\u003eBuried Foundations and Structures\u003c\/td\u003e\n\u003ctd data-start=\"4176\" data-end=\"4219\" data-col-size=\"md\"\u003eGenerally not an EM-locating application\u003c\/td\u003e\n\u003ctd data-start=\"4219\" data-end=\"4285\" data-col-size=\"md\"\u003eCan identify structural features and changes below the surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4286\" data-end=\"4404\"\u003e\n\u003ctd data-start=\"4286\" data-end=\"4316\" data-col-size=\"sm\"\u003eTrenches and Disturbed Soil\u003c\/td\u003e\n\u003ctd data-start=\"4316\" data-end=\"4341\" data-col-size=\"md\"\u003eNot typically detected\u003c\/td\u003e\n\u003ctd data-start=\"4341\" data-end=\"4404\" data-col-size=\"md\"\u003eCan reveal soil changes associated with previous excavation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4405\" data-end=\"4542\"\u003e\n\u003ctd data-start=\"4405\" data-end=\"4432\" data-col-size=\"sm\"\u003eUtility Depth Estimation\u003c\/td\u003e\n\u003ctd data-start=\"4432\" data-end=\"4480\" data-col-size=\"md\"\u003eAvailable under appropriate signal conditions\u003c\/td\u003e\n\u003ctd data-start=\"4480\" data-end=\"4542\" data-col-size=\"md\"\u003eDepth can be estimated from radar data and target geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4543\" data-end=\"4673\"\u003e\n\u003ctd data-start=\"4543\" data-end=\"4579\" data-col-size=\"sm\"\u003eComplete Subsurface Investigation\u003c\/td\u003e\n\u003ctd data-start=\"4579\" data-end=\"4623\" data-col-size=\"md\"\u003eFocused primarily on conductive utilities\u003c\/td\u003e\n\u003ctd data-start=\"4623\" data-end=\"4673\" data-col-size=\"md\"\u003eProvides broader subsurface imaging capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"1h0s8bu\" data-start=\"4675\" data-end=\"4695\"\u003eRD1100 vs. RD1500\u003c\/h2\u003e\n\u003cp data-start=\"4697\" data-end=\"4933\"\u003eThe RD1100 and RD1500 use ground penetrating radar technology to locate metallic and non-metallic subsurface targets. The main distinction is the level of mapping, georeferencing, and data-management capability required by the operator.\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"4935\" data-end=\"5946\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"4935\" data-end=\"4994\"\u003e\n\u003ctr data-start=\"4935\" data-end=\"4994\"\u003e\n\u003cth data-start=\"4935\" data-end=\"4945\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"4945\" data-end=\"4969\" data-col-size=\"md\" class=\"last:pe-10\"\u003eRadiodetection RD1100\u003c\/th\u003e\n\u003cth data-start=\"4969\" data-end=\"4994\" data-col-size=\"md\" class=\"last:pe-10\"\u003eRadiodetection RD1500\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"5009\" data-end=\"5946\"\u003e\n\u003ctr data-start=\"5009\" data-end=\"5157\"\u003e\n\u003ctd data-start=\"5009\" data-end=\"5023\" data-col-size=\"sm\"\u003ePrimary Use\u003c\/td\u003e\n\u003ctd data-start=\"5023\" data-end=\"5082\" data-col-size=\"md\"\u003eUtility detection and real-time subsurface investigation\u003c\/td\u003e\n\u003ctd data-start=\"5082\" data-end=\"5157\" data-col-size=\"md\"\u003eUtility detection, mapping, documentation, and advanced field workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5158\" data-end=\"5200\"\u003e\n\u003ctd data-start=\"5158\" data-end=\"5187\" data-col-size=\"sm\"\u003eMetallic Utility Detection\u003c\/td\u003e\n\u003ctd data-start=\"5187\" data-end=\"5193\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003ctd data-start=\"5193\" data-end=\"5200\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5201\" data-end=\"5247\"\u003e\n\u003ctd data-start=\"5201\" data-end=\"5234\" data-col-size=\"sm\"\u003eNon-Metallic Utility Detection\u003c\/td\u003e\n\u003ctd data-start=\"5234\" data-end=\"5240\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003ctd data-start=\"5240\" data-end=\"5247\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5248\" data-end=\"5388\"\u003e\n\u003ctd data-start=\"5248\" data-end=\"5281\" data-col-size=\"sm\"\u003eMaximum Stated Detection Depth\u003c\/td\u003e\n\u003ctd data-start=\"5281\" data-end=\"5334\" data-col-size=\"md\"\u003eUp to approximately 27 ft, depending on conditions\u003c\/td\u003e\n\u003ctd data-start=\"5334\" data-end=\"5388\" data-col-size=\"md\"\u003eUp to approximately 27 ft, depending on conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5389\" data-end=\"5424\"\u003e\n\u003ctd data-start=\"5389\" data-end=\"5411\" data-col-size=\"sm\"\u003eLine-Based Scanning\u003c\/td\u003e\n\u003ctd data-start=\"5411\" data-end=\"5417\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003ctd data-start=\"5417\" data-end=\"5424\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5425\" data-end=\"5449\"\u003e\n\u003ctd data-start=\"5425\" data-end=\"5437\" data-col-size=\"sm\"\u003eGrid Scan\u003c\/td\u003e\n\u003ctd data-start=\"5437\" data-end=\"5442\" data-col-size=\"md\"\u003eNo\u003c\/td\u003e\n\u003ctd data-start=\"5442\" data-end=\"5449\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5450\" data-end=\"5473\"\u003e\n\u003ctd data-start=\"5450\" data-end=\"5461\" data-col-size=\"sm\"\u003eMap View\u003c\/td\u003e\n\u003ctd data-start=\"5461\" data-end=\"5466\" data-col-size=\"md\"\u003eNo\u003c\/td\u003e\n\u003ctd data-start=\"5466\" data-end=\"5473\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5474\" data-end=\"5498\"\u003e\n\u003ctd data-start=\"5474\" data-end=\"5486\" data-col-size=\"sm\"\u003eSplitView\u003c\/td\u003e\n\u003ctd data-start=\"5486\" data-end=\"5491\" data-col-size=\"md\"\u003eNo\u003c\/td\u003e\n\u003ctd data-start=\"5491\" data-end=\"5498\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5499\" data-end=\"5588\"\u003e\n\u003ctd data-start=\"5499\" data-end=\"5526\" data-col-size=\"sm\"\u003eExternal GPS Integration\u003c\/td\u003e\n\u003ctd data-start=\"5526\" data-end=\"5575\" data-col-size=\"md\"\u003eNot identified as a standard RD1100 capability\u003c\/td\u003e\n\u003ctd data-start=\"5575\" data-end=\"5588\" data-col-size=\"md\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5589\" data-end=\"5710\"\u003e\n\u003ctd data-start=\"5589\" data-end=\"5632\" data-col-size=\"sm\"\u003eData Export for Advanced Post-Processing\u003c\/td\u003e\n\u003ctd data-start=\"5632\" data-end=\"5658\" data-col-size=\"md\"\u003eBasic USB data transfer\u003c\/td\u003e\n\u003ctd data-start=\"5658\" data-end=\"5710\" data-col-size=\"md\"\u003eEnhanced export and post-processing capabilities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5711\" data-end=\"5748\"\u003e\n\u003ctd data-start=\"5711\" data-end=\"5735\" data-col-size=\"sm\"\u003eWi-Fi Display Sharing\u003c\/td\u003e\n\u003ctd data-start=\"5735\" data-end=\"5741\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003ctd data-start=\"5741\" data-end=\"5748\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5749\" data-end=\"5946\"\u003e\n\u003ctd data-start=\"5749\" data-end=\"5767\" data-col-size=\"sm\"\u003eBest Suited For\u003c\/td\u003e\n\u003ctd data-start=\"5767\" data-end=\"5846\" data-col-size=\"md\"\u003eContractors and locating professionals needing straightforward GPR detection\u003c\/td\u003e\n\u003ctd data-start=\"5846\" data-end=\"5946\" data-col-size=\"md\"\u003eSUE firms, municipalities, engineers, and mapping professionals requiring advanced documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"8eecu\" data-start=\"5948\" data-end=\"6001\"\u003eWhich Radiodetection GPR System Should You Choose?\u003c\/h2\u003e\n\u003ch3 data-section-id=\"20t5yy\" data-start=\"6003\" data-end=\"6030\"\u003eChoose the RD1100 When:\u003c\/h3\u003e\n\u003cul data-start=\"6032\" data-end=\"6492\"\u003e\n\u003cli data-section-id=\"18xbp5b\" data-start=\"6032\" data-end=\"6102\"\u003eYour primary objective is detecting buried utilities and structures.\u003c\/li\u003e\n\u003cli data-section-id=\"1w80owr\" data-start=\"6103\" data-end=\"6160\"\u003eYou need to identify metallic and non-metallic targets.\u003c\/li\u003e\n\u003cli data-section-id=\"5ivl0b\" data-start=\"6161\" data-end=\"6230\"\u003eYou want a straightforward GPR system for real-time field locating.\u003c\/li\u003e\n\u003cli data-section-id=\"1pei46f\" data-start=\"6231\" data-end=\"6284\"\u003eYou need to investigate broken tracer-wire systems.\u003c\/li\u003e\n\u003cli data-section-id=\"ne0dln\" data-start=\"6285\" data-end=\"6366\"\u003eYou want to identify trenches, disturbed soil, or buried construction features.\u003c\/li\u003e\n\u003cli data-section-id=\"kmjgbq\" data-start=\"6367\" data-end=\"6439\"\u003eAdvanced GPS-based mapping and grid-survey workflows are not required.\u003c\/li\u003e\n\u003cli data-section-id=\"1cnari8\" data-start=\"6440\" data-end=\"6492\"\u003eYou prefer a more direct detection-focused system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"eyhncu\" data-start=\"6494\" data-end=\"6521\"\u003eChoose the RD1500 When:\u003c\/h3\u003e\n\u003cul data-start=\"6523\" data-end=\"6871\"\u003e\n\u003cli data-section-id=\"1i0kwu7\" data-start=\"6523\" data-end=\"6558\"\u003eYou require Grid Scan capability.\u003c\/li\u003e\n\u003cli data-section-id=\"124zwuv\" data-start=\"6559\" data-end=\"6606\"\u003eYou need Map View or SplitView functionality.\u003c\/li\u003e\n\u003cli data-section-id=\"14v1yzy\" data-start=\"6607\" data-end=\"6656\"\u003eYou want to integrate an external GPS receiver.\u003c\/li\u003e\n\u003cli data-section-id=\"c3caen\" data-start=\"6657\" data-end=\"6732\"\u003eYour work requires advanced post-processing, archiving, or GIS workflows.\u003c\/li\u003e\n\u003cli data-section-id=\"npo7ct\" data-start=\"6733\" data-end=\"6806\"\u003eYou perform Subsurface Utility Engineering or detailed utility mapping.\u003c\/li\u003e\n\u003cli data-section-id=\"nwdyeu\" data-start=\"6807\" data-end=\"6871\"\u003eYou need more comprehensive documentation of target positions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"19vd27d\" data-start=\"6873\" data-end=\"6894\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-start=\"6896\" data-end=\"6941\"\u003eThe Radiodetection RD1100 is well suited for:\u003c\/p\u003e\n\u003cul data-start=\"6943\" data-end=\"7546\"\u003e\n\u003cli data-section-id=\"e1kzw0\" data-start=\"6943\" data-end=\"6973\"\u003eUnderground utility locating\u003c\/li\u003e\n\u003cli data-section-id=\"1vqpnf4\" data-start=\"6974\" data-end=\"7000\"\u003ePrivate utility locating\u003c\/li\u003e\n\u003cli data-section-id=\"dflj1h\" data-start=\"7001\" data-end=\"7028\"\u003eUtility damage prevention\u003c\/li\u003e\n\u003cli data-section-id=\"199ocjh\" data-start=\"7029\" data-end=\"7064\"\u003ePre-excavation site investigation\u003c\/li\u003e\n\u003cli data-section-id=\"1eayinc\" data-start=\"7065\" data-end=\"7095\"\u003eConstruction site assessment\u003c\/li\u003e\n\u003cli data-section-id=\"ymxm0w\" data-start=\"7096\" data-end=\"7129\"\u003eMunicipal utility investigation\u003c\/li\u003e\n\u003cli data-section-id=\"gelh8c\" data-start=\"7130\" data-end=\"7151\"\u003eEngineering surveys\u003c\/li\u003e\n\u003cli data-section-id=\"1sir17\" data-start=\"7152\" data-end=\"7186\"\u003eEnvironmental site investigation\u003c\/li\u003e\n\u003cli data-section-id=\"1vxt2tq\" data-start=\"7187\" data-end=\"7220\"\u003eLocating undocumented utilities\u003c\/li\u003e\n\u003cli data-section-id=\"18yiyte\" data-start=\"7221\" data-end=\"7263\"\u003eInvestigating failed tracer-wire systems\u003c\/li\u003e\n\u003cli data-section-id=\"1nzfujf\" data-start=\"7264\" data-end=\"7298\"\u003eIdentifying old utility trenches\u003c\/li\u003e\n\u003cli data-section-id=\"gg1uay\" data-start=\"7299\" data-end=\"7335\"\u003eLocating underground storage tanks\u003c\/li\u003e\n\u003cli data-section-id=\"w0skw8\" data-start=\"7336\" data-end=\"7379\"\u003eDetecting buried manholes and splice pits\u003c\/li\u003e\n\u003cli data-section-id=\"rpa0yb\" data-start=\"7380\" data-end=\"7409\"\u003eIdentifying old foundations\u003c\/li\u003e\n\u003cli data-section-id=\"1ncnots\" data-start=\"7410\" data-end=\"7459\"\u003eLocating buried concrete or structural features\u003c\/li\u003e\n\u003cli data-section-id=\"3y1yn5\" data-start=\"7460\" data-end=\"7481\"\u003eExcavation planning\u003c\/li\u003e\n\u003cli data-section-id=\"sf7hh6\" data-start=\"7482\" data-end=\"7516\"\u003eRoad and infrastructure projects\u003c\/li\u003e\n\u003cli data-section-id=\"16c204s\" data-start=\"7517\" data-end=\"7546\"\u003eCommercial site development\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"7548\" data-end=\"7563\"\u003eKey Features\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1owklr4\" data-start=\"7565\" data-end=\"7612\"\u003eMetallic and Non-Metallic Utility Detection\u003c\/h3\u003e\n\u003cp data-start=\"7614\" data-end=\"7836\"\u003eThe RD1100 can detect both conductive and non-conductive subsurface targets under suitable ground conditions. This allows operators to investigate utilities that may not be locatable using an electromagnetic locator alone.\u003c\/p\u003e\n\u003ch3 data-section-id=\"837zfk\" data-start=\"7838\" data-end=\"7871\"\u003eUp to 27-Foot Detection Depth\u003c\/h3\u003e\n\u003cp data-start=\"7873\" data-end=\"8054\"\u003eThe system can detect targets at depths of up to approximately \u003cstrong data-start=\"7936\" data-end=\"7947\"\u003e27 feet\u003c\/strong\u003e, depending on soil conditions, target size, target orientation, moisture, and other environmental factors.\u003c\/p\u003e\n\u003ch3 data-section-id=\"18rbycx\" data-start=\"8056\" data-end=\"8094\"\u003e250 MHz Ultra-Wideband GPR Antenna\u003c\/h3\u003e\n\u003cp data-start=\"8096\" data-end=\"8258\"\u003eThe patented \u003cstrong data-start=\"8109\" data-end=\"8143\"\u003e250 MHz ultra-wideband antenna\u003c\/strong\u003e is designed to balance penetration depth with target resolution for utility locating and subsurface investigation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1umfrr0\" data-start=\"8260\" data-end=\"8296\"\u003eDynaT Dynamic Target Enhancement\u003c\/h3\u003e\n\u003cp data-start=\"8298\" data-end=\"8409\"\u003eDynaT technology improves target visibility by dynamically enhancing subsurface radar responses on the display.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1drkmuo\" data-start=\"8411\" data-end=\"8450\"\u003eHigh-Visibility Touchscreen Display\u003c\/h3\u003e\n\u003cp data-start=\"8452\" data-end=\"8551\"\u003eThe touchscreen display is designed for outdoor field use and can be operated while wearing gloves.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kzj4za\" data-start=\"8553\" data-end=\"8571\"\u003eBuilt-In Wi-Fi\u003c\/h3\u003e\n\u003cp data-start=\"8573\" data-end=\"8682\"\u003eBuilt-in Wi-Fi allows field personnel to share display images and site information directly from the jobsite.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13ij849\" data-start=\"8684\" data-end=\"8705\"\u003eUSB Data Transfer\u003c\/h3\u003e\n\u003cp data-start=\"8707\" data-end=\"8817\"\u003eThe integrated USB port allows data to be transferred for documentation, storage, review, and project records.\u003c\/p\u003e\n\u003ch3 data-section-id=\"4bt0vi\" data-start=\"8819\" data-end=\"8865\"\u003eUS Standard and Metric Measurement Options\u003c\/h3\u003e\n\u003cp data-start=\"8867\" data-end=\"8967\"\u003eOperators can configure the system to display measurements using either US standard or metric units.\u003c\/p\u003e\n\u003ch3 data-section-id=\"8jokna\" data-start=\"8969\" data-end=\"8993\"\u003eLong-Lasting Battery\u003c\/h3\u003e\n\u003cp data-start=\"8995\" data-end=\"9093\"\u003eThe RD1100 uses a rechargeable lead-acid gel battery designed to support extended field operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"asrffi\" data-start=\"9095\" data-end=\"9126\"\u003eCollapsible Fiberglass Cart\u003c\/h3\u003e\n\u003cp data-start=\"9128\" data-end=\"9259\"\u003eThe lightweight fiberglass cart folds for easier transportation and storage while providing a stable platform during field surveys.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"9261\" data-end=\"9288\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"9290\" data-end=\"10394\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"9290\" data-end=\"9317\"\u003e\n\u003ctr data-start=\"9290\" data-end=\"9317\"\u003e\n\u003cth data-start=\"9290\" data-end=\"9306\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"9306\" data-end=\"9317\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"9328\" data-end=\"10394\"\u003e\n\u003ctr data-start=\"9328\" data-end=\"9378\"\u003e\n\u003ctd data-start=\"9328\" data-end=\"9343\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"9343\" data-end=\"9378\" data-col-size=\"md\"\u003eGround Penetrating Radar System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9379\" data-end=\"9404\"\u003e\n\u003ctd data-start=\"9379\" data-end=\"9394\" data-col-size=\"sm\"\u003eModel Number\u003c\/td\u003e\n\u003ctd data-start=\"9394\" data-end=\"9404\" data-col-size=\"md\"\u003eRD1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9405\" data-end=\"9482\"\u003e\n\u003ctd data-start=\"9405\" data-end=\"9427\" data-col-size=\"sm\"\u003ePrimary Application\u003c\/td\u003e\n\u003ctd data-start=\"9427\" data-end=\"9482\" data-col-size=\"md\"\u003eUnderground utility and subsurface target detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9483\" data-end=\"9534\"\u003e\n\u003ctd data-start=\"9483\" data-end=\"9506\" data-col-size=\"sm\"\u003eDetection Technology\u003c\/td\u003e\n\u003ctd data-start=\"9506\" data-end=\"9534\" data-col-size=\"md\"\u003eGround Penetrating Radar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9535\" data-end=\"9592\"\u003e\n\u003ctd data-start=\"9535\" data-end=\"9545\" data-col-size=\"sm\"\u003eAntenna\u003c\/td\u003e\n\u003ctd data-start=\"9545\" data-end=\"9592\" data-col-size=\"md\"\u003ePatented ultra-wideband 250 MHz GPR antenna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9593\" data-end=\"9650\"\u003e\n\u003ctd data-start=\"9593\" data-end=\"9614\" data-col-size=\"sm\"\u003eTarget Enhancement\u003c\/td\u003e\n\u003ctd data-start=\"9614\" data-end=\"9650\" data-col-size=\"md\"\u003eDynaT dynamic target enhancement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9651\" data-end=\"9756\"\u003e\n\u003ctd data-start=\"9651\" data-end=\"9684\" data-col-size=\"sm\"\u003eMaximum Stated Detection Depth\u003c\/td\u003e\n\u003ctd data-start=\"9684\" data-end=\"9756\" data-col-size=\"md\"\u003eUp to approximately 27 ft, depending on ground and target conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9757\" data-end=\"9793\"\u003e\n\u003ctd data-start=\"9757\" data-end=\"9786\" data-col-size=\"sm\"\u003eMetallic Utility Detection\u003c\/td\u003e\n\u003ctd data-start=\"9786\" data-end=\"9793\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9794\" data-end=\"9834\"\u003e\n\u003ctd data-start=\"9794\" data-end=\"9827\" data-col-size=\"sm\"\u003eNon-Metallic Utility Detection\u003c\/td\u003e\n\u003ctd data-start=\"9827\" data-end=\"9834\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9835\" data-end=\"9880\"\u003e\n\u003ctd data-start=\"9835\" data-end=\"9873\" data-col-size=\"sm\"\u003eTrench and Disturbed Soil Detection\u003c\/td\u003e\n\u003ctd data-start=\"9873\" data-end=\"9880\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9881\" data-end=\"9921\"\u003e\n\u003ctd data-start=\"9881\" data-end=\"9914\" data-col-size=\"sm\"\u003eUndocumented Utility Detection\u003c\/td\u003e\n\u003ctd data-start=\"9914\" data-end=\"9921\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9922\" data-end=\"9963\"\u003e\n\u003ctd data-start=\"9922\" data-end=\"9932\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"9932\" data-end=\"9963\" data-col-size=\"md\"\u003eHigh-visibility touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"9964\" data-end=\"10000\"\u003e\n\u003ctd data-start=\"9964\" data-end=\"9993\" data-col-size=\"sm\"\u003eGlove-Compatible Operation\u003c\/td\u003e\n\u003ctd data-start=\"9993\" data-end=\"10000\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10001\" data-end=\"10047\"\u003e\n\u003ctd data-start=\"10001\" data-end=\"10021\" data-col-size=\"sm\"\u003eMeasurement Units\u003c\/td\u003e\n\u003ctd data-start=\"10021\" data-end=\"10047\" data-col-size=\"md\"\u003eUS standard and metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10048\" data-end=\"10068\"\u003e\n\u003ctd data-start=\"10048\" data-end=\"10056\" data-col-size=\"sm\"\u003eWi-Fi\u003c\/td\u003e\n\u003ctd data-start=\"10056\" data-end=\"10068\" data-col-size=\"md\"\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10069\" data-end=\"10087\"\u003e\n\u003ctd data-start=\"10069\" data-end=\"10080\" data-col-size=\"sm\"\u003eUSB Port\u003c\/td\u003e\n\u003ctd data-start=\"10080\" data-end=\"10087\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10088\" data-end=\"10141\"\u003e\n\u003ctd data-start=\"10088\" data-end=\"10103\" data-col-size=\"sm\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd data-start=\"10103\" data-end=\"10141\" data-col-size=\"md\"\u003eRechargeable lead-acid gel battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10142\" data-end=\"10188\"\u003e\n\u003ctd data-start=\"10142\" data-end=\"10162\" data-col-size=\"sm\"\u003eCart Construction\u003c\/td\u003e\n\u003ctd data-start=\"10162\" data-end=\"10188\" data-col-size=\"md\"\u003eLightweight fiberglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10189\" data-end=\"10218\"\u003e\n\u003ctd data-start=\"10189\" data-end=\"10203\" data-col-size=\"sm\"\u003eCart Design\u003c\/td\u003e\n\u003ctd data-start=\"10203\" data-end=\"10218\" data-col-size=\"md\"\u003eCollapsible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10219\" data-end=\"10237\"\u003e\n\u003ctd data-start=\"10219\" data-end=\"10231\" data-col-size=\"sm\"\u003eGrid Scan\u003c\/td\u003e\n\u003ctd data-start=\"10231\" data-end=\"10237\" data-col-size=\"md\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10238\" data-end=\"10255\"\u003e\n\u003ctd data-start=\"10238\" data-end=\"10249\" data-col-size=\"sm\"\u003eMap View\u003c\/td\u003e\n\u003ctd data-start=\"10249\" data-end=\"10255\" data-col-size=\"md\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10256\" data-end=\"10319\"\u003e\n\u003ctd data-start=\"10256\" data-end=\"10279\" data-col-size=\"sm\"\u003eExternal GPS Mapping\u003c\/td\u003e\n\u003ctd data-start=\"10279\" data-end=\"10319\" data-col-size=\"md\"\u003eNot identified as a standard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"10320\" data-end=\"10394\"\u003e\n\u003ctd data-start=\"10320\" data-end=\"10354\" data-col-size=\"sm\"\u003eAdvanced Post-Processing Export\u003c\/td\u003e\n\u003ctd data-start=\"10354\" data-end=\"10394\" data-col-size=\"md\"\u003eNot identified as a standard feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"1nnqinw\" data-start=\"10396\" data-end=\"10442\"\u003eGround Conditions and Detection Performance\u003c\/h2\u003e\n\u003cp data-start=\"10444\" data-end=\"10609\"\u003eGround penetrating radar performance varies from one site to another. The RD1100 does not provide the same detection depth or target visibility in every environment.\u003c\/p\u003e\n\u003cp data-start=\"10611\" data-end=\"10642\"\u003ePerformance may be affected by:\u003c\/p\u003e\n\u003cul data-start=\"10644\" data-end=\"10876\"\u003e\n\u003cli data-section-id=\"udizrd\" data-start=\"10644\" data-end=\"10655\"\u003eSoil type\u003c\/li\u003e\n\u003cli data-section-id=\"gswt4m\" data-start=\"10656\" data-end=\"10670\"\u003eClay content\u003c\/li\u003e\n\u003cli data-section-id=\"uyw83y\" data-start=\"10671\" data-end=\"10690\"\u003eSoil conductivity\u003c\/li\u003e\n\u003cli data-section-id=\"1llkgrz\" data-start=\"10691\" data-end=\"10709\"\u003eMoisture content\u003c\/li\u003e\n\u003cli data-section-id=\"1itv4sz\" data-start=\"10710\" data-end=\"10730\"\u003eSalt concentration\u003c\/li\u003e\n\u003cli data-section-id=\"1qd19uc\" data-start=\"10731\" data-end=\"10745\"\u003eTarget depth\u003c\/li\u003e\n\u003cli data-section-id=\"1josi3g\" data-start=\"10746\" data-end=\"10759\"\u003eTarget size\u003c\/li\u003e\n\u003cli data-section-id=\"1y169gy\" data-start=\"10760\" data-end=\"10777\"\u003eTarget material\u003c\/li\u003e\n\u003cli data-section-id=\"1kno41b\" data-start=\"10778\" data-end=\"10798\"\u003eTarget orientation\u003c\/li\u003e\n\u003cli data-section-id=\"1a0ybtp\" data-start=\"10799\" data-end=\"10819\"\u003eSurface conditions\u003c\/li\u003e\n\u003cli data-section-id=\"1ebq1vx\" data-start=\"10820\" data-end=\"10838\"\u003eNearby utilities\u003c\/li\u003e\n\u003cli data-section-id=\"1wi2z8r\" data-start=\"10839\" data-end=\"10858\"\u003eReinforcing steel\u003c\/li\u003e\n\u003cli data-section-id=\"plmw7g\" data-start=\"10859\" data-end=\"10876\"\u003eSite congestion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"10878\" data-end=\"11035\"\u003eDry sand and other low-conductivity soils generally allow deeper radar penetration than highly conductive soils such as wet clay or salt-contaminated ground.\u003c\/p\u003e\n\u003cp data-start=\"11037\" data-end=\"11201\"\u003eBecause of these variables, the stated maximum depth of approximately 27 feet should not be interpreted as a guaranteed detection depth for every target or jobsite.\u003c\/p\u003e\n\u003ch2 data-section-id=\"ciwxli\" data-start=\"11203\" data-end=\"11235\"\u003eRecommended Locating Workflow\u003c\/h2\u003e\n\u003cp data-start=\"11237\" data-end=\"11372\"\u003eFor the most complete underground investigation, operators should combine the RD1100 with other locating and site-verification methods.\u003c\/p\u003e\n\u003cp data-start=\"11374\" data-end=\"11419\"\u003eA professional locating workflow may include:\u003c\/p\u003e\n\u003col data-start=\"11421\" data-end=\"11853\"\u003e\n\u003cli data-section-id=\"17f7ga\" data-start=\"11421\" data-end=\"11478\"\u003eReviewing available utility records and site drawings.\u003c\/li\u003e\n\u003cli data-section-id=\"1kb38cm\" data-start=\"11479\" data-end=\"11518\"\u003ePerforming a visual site inspection.\u003c\/li\u003e\n\u003cli data-section-id=\"12oqj1y\" data-start=\"11519\" data-end=\"11579\"\u003eUsing an electromagnetic locator on conductive utilities.\u003c\/li\u003e\n\u003cli data-section-id=\"k5k6pm\" data-start=\"11580\" data-end=\"11621\"\u003eScanning the site with the RD1100 GPR.\u003c\/li\u003e\n\u003cli data-section-id=\"6myx4\" data-start=\"11622\" data-end=\"11673\"\u003eSurveying in multiple directions when practical.\u003c\/li\u003e\n\u003cli data-section-id=\"lo6rh3\" data-start=\"11674\" data-end=\"11724\"\u003eComparing GPR findings with EM-locator results.\u003c\/li\u003e\n\u003cli data-section-id=\"1vna2vk\" data-start=\"11725\" data-end=\"11755\"\u003eMarking identified targets.\u003c\/li\u003e\n\u003cli data-section-id=\"h9qvnk\" data-start=\"11756\" data-end=\"11853\"\u003eUsing vacuum excavation, potholing, or another approved verification method before excavation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"11855\" data-end=\"12050\"\u003eThe RD1100 provides subsurface information but does not eliminate the need for professional judgment, proper training, utility notifications, safe excavation procedures, or physical verification.\u003c\/p\u003e\n\u003ch2 data-section-id=\"xydb7h\" data-start=\"12052\" data-end=\"12070\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cp data-start=\"12072\" data-end=\"12189\"\u003eThe exact package configuration should be confirmed when requesting a quotation. A typical RD1100 system may include:\u003c\/p\u003e\n\u003cul data-start=\"12191\" data-end=\"12424\"\u003e\n\u003cli data-section-id=\"165xg00\" data-start=\"12191\" data-end=\"12225\"\u003eRadiodetection RD1100 GPR system\u003c\/li\u003e\n\u003cli data-section-id=\"1pt8kam\" data-start=\"12226\" data-end=\"12263\"\u003eHigh-visibility touchscreen display\u003c\/li\u003e\n\u003cli data-section-id=\"1tqo0ca\" data-start=\"12264\" data-end=\"12285\"\u003e250 MHz GPR antenna\u003c\/li\u003e\n\u003cli data-section-id=\"11d59kg\" data-start=\"12286\" data-end=\"12315\"\u003eCollapsible fiberglass cart\u003c\/li\u003e\n\u003cli data-section-id=\"1uzubdu\" data-start=\"12316\" data-end=\"12352\"\u003eRechargeable lead-acid gel battery\u003c\/li\u003e\n\u003cli data-section-id=\"1c087zh\" data-start=\"12353\" data-end=\"12370\"\u003eBattery charger\u003c\/li\u003e\n\u003cli data-section-id=\"ribmpq\" data-start=\"12371\" data-end=\"12395\"\u003eRequired system cables\u003c\/li\u003e\n\u003cli data-section-id=\"1795g99\" data-start=\"12396\" data-end=\"12424\"\u003eManufacturer documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"12426\" data-end=\"12538\"\u003eContact Titan Tools Direct to verify the current package contents, accessories, availability, and configuration.\u003c\/p\u003e\n\u003ch2 data-section-id=\"k9s32o\" data-start=\"12540\" data-end=\"12580\"\u003eWhy Choose the Radiodetection RD1100?\u003c\/h2\u003e\n\u003cp data-start=\"12582\" data-end=\"12726\"\u003eThe RD1100 is designed for organizations that need a practical, field-ready GPR system without the advanced mapping functionality of the RD1500.\u003c\/p\u003e\n\u003cp data-start=\"12728\" data-end=\"12764\"\u003eIt provides a strong combination of:\u003c\/p\u003e\n\u003cul data-start=\"12766\" data-end=\"13010\"\u003e\n\u003cli data-section-id=\"5ph05b\" data-start=\"12766\" data-end=\"12810\"\u003eMetallic and non-metallic target detection\u003c\/li\u003e\n\u003cli data-section-id=\"gw6dbw\" data-start=\"12811\" data-end=\"12837\"\u003eUseful depth penetration\u003c\/li\u003e\n\u003cli data-section-id=\"1ghcgom\" data-start=\"12838\" data-end=\"12874\"\u003eHigh-resolution subsurface imaging\u003c\/li\u003e\n\u003cli data-section-id=\"sobmd6\" data-start=\"12875\" data-end=\"12905\"\u003eSimple touchscreen operation\u003c\/li\u003e\n\u003cli data-section-id=\"zzwaoy\" data-start=\"12906\" data-end=\"12934\"\u003ePortable cart construction\u003c\/li\u003e\n\u003cli data-section-id=\"15wz97e\" data-start=\"12935\" data-end=\"12961\"\u003eWireless display sharing\u003c\/li\u003e\n\u003cli data-section-id=\"1l4gz93\" data-start=\"12962\" data-end=\"12981\"\u003eUSB data transfer\u003c\/li\u003e\n\u003cli data-section-id=\"4976o7\" data-start=\"12982\" data-end=\"13010\"\u003eRugged field functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"13012\" data-end=\"13238\"\u003eFor utility locators, contractors, municipalities, and engineering teams, the RD1100 can help reduce uncertainty before excavation and improve confidence when investigating difficult or undocumented underground infrastructure.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1r8frcv\" data-start=\"13240\" data-end=\"13269\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 data-section-id=\"18bk9ac\" data-start=\"13271\" data-end=\"13318\"\u003eWhat is the Radiodetection RD1100 used for?\u003c\/h3\u003e\n\u003cp data-start=\"13320\" data-end=\"13502\"\u003eThe RD1100 is used to detect buried metallic and non-metallic utilities, storage tanks, manholes, trenches, foundations, and other subsurface features using ground penetrating radar.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1pvbmv7\" data-start=\"13504\" data-end=\"13539\"\u003eCan the RD1100 locate PVC pipe?\u003c\/h3\u003e\n\u003cp data-start=\"13541\" data-end=\"13764\"\u003eThe RD1100 can detect PVC and other non-metallic pipe when the pipe creates sufficient contrast with the surrounding soil. Detection is affected by soil conditions, target size, depth, moisture, and installation conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1o9193s\" data-start=\"13766\" data-end=\"13827\"\u003eCan the RD1100 locate utilities with broken tracer wires?\u003c\/h3\u003e\n\u003cp data-start=\"13829\" data-end=\"13981\"\u003eYes. Because GPR does not depend on a functioning tracer wire, it can help identify utilities when the tracer wire is missing, damaged, or inaccessible.\u003c\/p\u003e\n\u003ch3 data-section-id=\"uring9\" data-start=\"13983\" data-end=\"14018\"\u003eHow deep can the RD1100 detect?\u003c\/h3\u003e\n\u003cp data-start=\"14020\" data-end=\"14231\"\u003eThe stated maximum depth is up to approximately \u003cstrong data-start=\"14068\" data-end=\"14079\"\u003e27 feet\u003c\/strong\u003e, depending on ground conditions, target size, target composition, and site conditions. Maximum depth is not guaranteed for every target or environment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"mrt52d\" data-start=\"14233\" data-end=\"14301\"\u003eDoes the RD1100 locate both metallic and non-metallic utilities?\u003c\/h3\u003e\n\u003cp data-start=\"14303\" data-end=\"14426\"\u003eYes. The RD1100 can identify both metallic and non-metallic targets when site conditions provide sufficient radar contrast.\u003c\/p\u003e\n\u003ch3 data-section-id=\"6skzrs\" data-start=\"14428\" data-end=\"14483\"\u003eDoes the RD1100 replace an electromagnetic locator?\u003c\/h3\u003e\n\u003cp data-start=\"14485\" data-end=\"14729\"\u003eNo. GPR and electromagnetic locating technologies are complementary. EM equipment is generally preferred for tracing conductive utilities, while GPR can help locate non-conductive utilities, structures, trenches, and unknown subsurface targets.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1kt9j2o\" data-start=\"14731\" data-end=\"14769\"\u003eDoes the RD1100 include Grid Scan?\u003c\/h3\u003e\n\u003cp data-start=\"14771\" data-end=\"14835\"\u003eNo. Grid Scan is an advanced feature associated with the RD1500.\u003c\/p\u003e\n\u003ch3 data-section-id=\"9zj4ks\" data-start=\"14837\" data-end=\"14877\"\u003eDoes the RD1100 support GPS mapping?\u003c\/h3\u003e\n\u003cp data-start=\"14879\" data-end=\"15058\"\u003eThe provided RD1100 specifications do not identify external GPS mapping as a standard capability. Buyers requiring advanced GPS integration and mapping should consider the RD1500.\u003c\/p\u003e\n\u003ch3 data-section-id=\"54nmga\" data-start=\"15060\" data-end=\"15112\"\u003eCan the RD1100 detect underground storage tanks?\u003c\/h3\u003e\n\u003cp data-start=\"15114\" data-end=\"15248\"\u003eYes. The RD1100 can help detect underground storage tanks and other large buried targets when soil and target conditions are suitable.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iiabj3\" data-start=\"15250\" data-end=\"15303\"\u003eCan the touchscreen be used while wearing gloves?\u003c\/h3\u003e\n\u003cp data-start=\"15305\" data-end=\"15399\"\u003eYes. The high-visibility touchscreen is designed to work while the operator is wearing gloves.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1uo31bh\" data-start=\"15401\" data-end=\"15432\"\u003eDoes the RD1100 have Wi-Fi?\u003c\/h3\u003e\n\u003cp data-start=\"15434\" data-end=\"15520\"\u003eYes. Built-in Wi-Fi allows users to share display information directly from the field.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ffs8eu\" data-start=\"15522\" data-end=\"15550\"\u003eIs training recommended?\u003c\/h3\u003e\n\u003cp data-start=\"15552\" data-end=\"15730\"\u003eYes. Proper training is important for interpreting GPR data, understanding site limitations, identifying false positives, and integrating GPR results with other locating methods.\u003c\/p\u003e\n\u003ch2 data-section-id=\"11sqix0\" data-start=\"15732\" data-end=\"15767\"\u003eWhy Buy From Titan Tools Direct?\u003c\/h2\u003e\n\u003cul data-start=\"15769\" data-end=\"16096\"\u003e\n\u003cli data-section-id=\"18wyhbo\" data-start=\"15769\" data-end=\"15788\"\u003eAuthorized Dealer\u003c\/li\u003e\n\u003cli data-section-id=\"1m6et8n\" data-start=\"15789\" data-end=\"15810\"\u003eCompetitive Pricing\u003c\/li\u003e\n\u003cli data-section-id=\"1lmm3a0\" data-start=\"15811\" data-end=\"15854\"\u003eCall for Pricing and Product Consultation\u003c\/li\u003e\n\u003cli data-section-id=\"hjrv7q\" data-start=\"15855\" data-end=\"15901\"\u003eFree On-Site Demonstrations in Select States\u003c\/li\u003e\n\u003cli data-section-id=\"yv0fee\" data-start=\"15902\" data-end=\"15928\"\u003eFast Nationwide Shipping\u003c\/li\u003e\n\u003cli data-section-id=\"17fqxy1\" data-start=\"15929\" data-end=\"15965\"\u003eExpert Sales and Technical Support\u003c\/li\u003e\n\u003cli data-section-id=\"14neuwj\" data-start=\"15966\" data-end=\"16051\"\u003eTrusted by Contractors, Surveyors, Utility Locators, and Construction Professionals\u003c\/li\u003e\n\u003cli data-section-id=\"1vr0kd3\" data-start=\"16052\" data-end=\"16096\"\u003eCustomer Support Before and After the Sale\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"asp0uv\" data-start=\"16098\" data-end=\"16138\"\u003eSchedule a FREE On-Site Demonstration\u003c\/h2\u003e\n\u003cp data-start=\"16140\" data-end=\"16231\"\u003eFREE on-site Radiodetection RD1100 demonstrations are available for qualified customers in:\u003c\/p\u003e\n\u003cul data-start=\"16233\" data-end=\"16399\"\u003e\n\u003cli data-section-id=\"l57571\" data-start=\"16233\" data-end=\"16243\"\u003eVirginia\u003c\/li\u003e\n\u003cli data-section-id=\"1djuojc\" data-start=\"16244\" data-end=\"16259\"\u003eWest Virginia\u003c\/li\u003e\n\u003cli data-section-id=\"w7a8dk\" data-start=\"16260\" data-end=\"16270\"\u003eMaryland\u003c\/li\u003e\n\u003cli data-section-id=\"11kxcyt\" data-start=\"16271\" data-end=\"16281\"\u003eDelaware\u003c\/li\u003e\n\u003cli data-section-id=\"1wt3pk6\" data-start=\"16282\" data-end=\"16294\"\u003eNew Jersey\u003c\/li\u003e\n\u003cli data-section-id=\"amzdii\" data-start=\"16295\" data-end=\"16309\"\u003ePennsylvania\u003c\/li\u003e\n\u003cli data-section-id=\"6lczcx\" data-start=\"16310\" data-end=\"16324\"\u003eRhode Island\u003c\/li\u003e\n\u003cli data-section-id=\"1e5b75n\" data-start=\"16325\" data-end=\"16335\"\u003eNew York\u003c\/li\u003e\n\u003cli data-section-id=\"1hnttx9\" data-start=\"16336\" data-end=\"16349\"\u003eConnecticut\u003c\/li\u003e\n\u003cli data-section-id=\"mudcim\" data-start=\"16350\" data-end=\"16365\"\u003eMassachusetts\u003c\/li\u003e\n\u003cli data-section-id=\"t25v3l\" data-start=\"16366\" data-end=\"16375\"\u003eVermont\u003c\/li\u003e\n\u003cli data-section-id=\"f3mybp\" data-start=\"16376\" data-end=\"16391\"\u003eNew Hampshire\u003c\/li\u003e\n\u003cli data-section-id=\"16vtd8m\" data-start=\"16392\" data-end=\"16399\"\u003eMaine\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"16401\" data-end=\"16513\"\u003eDemonstration availability may depend on customer location, project requirements, scheduling, and qualification.\u003c\/p\u003e\n\u003ch2 data-section-id=\"3esxkg\" data-start=\"16515\" data-end=\"16547\"\u003eQuestions or Request a Quote?\u003c\/h2\u003e\n\u003cp data-start=\"16549\" data-end=\"16684\"\u003eContact Titan Tools Direct for pricing, availability, demonstrations, accessories, and assistance comparing the RD1100 with the RD1500.\u003c\/p\u003e\n\u003cp data-start=\"16686\" data-end=\"16716\"\u003e\u003cstrong data-start=\"16686\" data-end=\"16703\"\u003eCall or Text:\u003c\/strong\u003e 832-727-9353\u003c\/p\u003e\n\u003cp data-start=\"16718\" data-end=\"16755\"\u003e\u003cstrong data-start=\"16718\" data-end=\"16728\"\u003eEmail:\u003c\/strong\u003e \u003ca data-start=\"16729\" data-end=\"16755\" class=\"decorated-link cursor-pointer\" rel=\"noopener\"\u003eSales@TitanToolsDirect.com\u003c\/a\u003e\u003c\/p\u003e","brand":"Radio Detection","offers":[{"title":"Default Title","offer_id":47902556258462,"sku":"ET11210","price":25000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/8990\/3518\/files\/RD1100-500x500.jpg?v=1782414291","url":"https:\/\/titantoolsdirect.com\/products\/radiodetection-rd1100-ground-penetrating-radar","provider":"Titan Tools Direct","version":"1.0","type":"link"}