Generac PWRcell Outdoor Rated (OR) Battery Cabinet
Model Number: APKE00042
The Generac PWRcell Outdoor Rated (OR) Battery Cabinet allows for various storage configurations to suit any need. DC-couple to Generac PWRzone solar or PWR generator. No other smart battery offers the power and flexibility of PWRcell. It also allows system owners to scale from an economical 9kWh to a massive 18kWh by installing additional battery modules to the PWRcell Battery Cabinet. An existing PWRcell Battery Cabinet can be upgraded with additional modules. Use the graphic below and the chart on the back of this sheet to understand what components you need for your chosen PWRcell configuration.
PWRcell Battery Cabinet Design: - The PWRcell Battery Cabinet allows system owners the flexibility to scale from an economical 9kWh to a mas- sive 18kWh by installing additional battery modules to the PWRcell Battery Cabinet. An existing PWRcell Battery Cabinet can beupgraded with additional modules. Use the graphic below and the chart on the back of this sheet to understand what components you need for your chosen PWRcell configuration.
Features and Benefits: - Best-in-class battery backup power
- Connect 2 PWRcell Battery Cabinets to a single PWRcell Inverter for up to 36kWh of usable storage
- Plug-and-play with all PWRcell products
- Time-of-use (TOU) and zero-export ready
- NEMA 3R cabinet for outdoor and indoor installations
- Floor standing or wall-mounted design
Specifications: - PWRcell™ BATTERY CONFIGURATIONS
- M3
- Battwery Modules: 3
- Usable Enegy¹: 9 kWh
- Nominal cont. Ac power¹,²: 3.4 kW
- Max. Ac power¹,³: 4.5 kW
- Nominal cont. Rebus dc current (charge/discharge) - a: 11.6
- Peak motor starting current (2 sec) - a, rms: 25
- M4
- Battwery Modules: 4
- Usable Enegy¹: 12 kWh
- Nominal cont. Ac power¹,²: 4.5 kW
- Max. Ac power¹,³: 6 kW
- Nominal cont. Rebus dc current (charge/discharge) - a: 15.5
- Peak motor starting current (2 sec) - a, rms: 33
- M5
- Battwery Modules: 5
- Usable Enegy¹: 15 kWh
- Nominal cont. Ac power¹,²: 5.6 kW
- Max. Ac power¹,³: 7.5 kW
- Nominal cont. Rebus dc current (charge/discharge) - a: 19.4
- Peak motor starting current (2 sec) - a, rms: 42
- M6
- Battwery Modules: 6
- Usable Enegy¹: 18 kWh
- Nominal cont. Ac power¹,²: 6.7 kW
- Max. Ac power¹,³: 9 kW
- Nominal cont. Rebus dc current (charge/discharge) - a: 23.3
- Peak motor starting current (2 sec) - a, rms: 50
- Compatible battery modules?: Generac pwrcell DCB 3.0 kWh
- Rebus™ VOLTAGE - INPUT/OUTPUT: 360-420 VDC
- Nominal voltage: 380 VDC
- Dc-dc round-trip efficiency: 96.5%
- Full performance temperature range (charging)?: 59 to 104 °f (15 to 40 °c)
- Full performance temperature range (discharging)?: 32 to 104 °f (0 to 40 °c)
- Maximum operating temperature range (charging)?: 41 to 122 °f (5 to 50 °c)
- Maximum operating temperature RANGE (DISCHARGING)?: 14 to 122 °F (-10 to 50 °c) maximum installation altitude - ft (m): 6560 (2000)
- Dimensions, l x w x h - in (mm): 22" x 10" x 68" (559 x 254 x 1727)
- Weight, enclosure - lb (kg): 115 (52)
- Weight, installed w/ DCB modules - lb (kg): 280 (127)
- (202) weight, accessory mounting hardware - lb (kg): 21 (10)
- Enclosure type: Type 3R
- Warranty - li-ion modules: 10 years, (7.56mwh)
- Warranty - electronics and enclosure: 10 years
- Communication protocol: Rebus™ dc nanogrid™
- Seismic rating: IEEE 693-2018 (high)
- Compliance: UL 9540, UL 9540A6, UL 1973, UL 1642, CSA 22.2 #107.1
Assumes use of 3.0kwh battery module. | Average AC power over a complete discharge cycle. | Values provided for 40ºc (104ºf). | All pwrcell battery models used in a pwrcell Battery Cabinet must be the same model. Do NOT combine module skus in a single battery cabinet. | Reference the pwrcell Battery Installation and Owner’s Manual for a detailed deration curve. | 4th ed. Tested at unit-level when installed with DCB battery modules and OR enclosure. Note: Charge/discharge rate may be reduced at temperature extremes.
Generac offers a Foot Bracket Accessory Kit (Model #APKE00043) for the pwrcell Battery Cabinet that is available for installations where a foot bracket mount is required.
Info and Guides: Click Here for Spec Sheet
*Spec sheet might include optional accessories not included with this purchase
Please Note the List of Items Below That Are Non-Returnable:
- Special Order items including but not limited to whole house or stationary generators
- Whole goods and attachments, literature, engines, pumps, short blocks, electrical parts, gaskets, liquids, chemicals, sprays
- Items with damaged or non-original packaging
- Installed, used or damaged items
Cancellation Policy Summary - Air-Cooled Product & short lead time Liquid-Cooled Product (60kW and smaller)
- Orders cancelled within 6 weeks of original ship date – 10% CANCELLATION FEE
- Shipped Orders – 15% CANCELLATION FEE
- Orders cancelled within 72 hours (calendar) of receipt – NO FEE
- Long lead time Liquid-Cooled Product (80kW to 150kW)
- Orders cancelled within 12 weeks of original ship date – 15% CANCELLATION FEE
- Shipped Orders – NO CANCELLATION ALLOWED
- Orders cancelled within 72hrs (calendar) of order receipt – NO FEE
- Protector Plus / Configured Product
- Cancellation within 20 weeks of original ship date – 10% CANCELLATION FEE
- Cancellation within 18 weeks of original ship date – 20% CANCELLATION FEE
- Cancellation within 16 weeks of original ship date – 30% CANCELLATION FEE
- Cancellation within 15 weeks of original ship date – 40% CANCELLATION FEE
- Orders cancelled within 72hrs (calendar) of order receipt – NO FEE